Spotlight
Facilities
Head
Faculty
Coordinators and Dy-Coordinators
User Committees
Staff
Student Homepages
How to Reach Us
IITR Home
Instrument Status
Log Reports
Powder X-Ray Diffrectometer (XRD)
General Information-
Make- Bruker
Model- D8-Advance
Year of Installation- 2008
 
 
 
Specification-
X-Ray Source : 2.2kW Cu anode, 40 kV/40 mA
Detector : LINXEYE XE
Smallest angular step size: 0.0001o
Reproducibility : +/- 0.0001o
Angular range (2Theta): 5o to 120o
 
About Instrument and its applications-
X-ray Diffraction (XRD) is a high-tech, non-destructive technique for analyzing a wide range of materials, including fluids, metals, minerals, polymers, catalysts, plastics, pharmaceuticals, thin-film coatings, ceramics, solar cells and semiconductors. Throughout industry and research institutions, XRD has become an indispensable method for materials investigation, characterization and quality control. Example areas of application include qualitative and quantitative phase analysis, crystallography, structure and relaxation determination, texture and residual stress investigations.
The Bruker D8 X-ray diffract meters are designed to easily accommodate all X-ray diffraction applications in material research, powder diffraction and high resolution diffraction. All new D8 goniometry are equipped with stepper motors with optical encoder to ensure extremely precise angular values. The D8 X-ray Diffractrometer can be used for nearly all X-ray diffraction application, such as structure determination, phase analysis, stress and texture measurement.
 
Sample Requirements-
Amount- 1g (in fine powder form)
 
Analytical Charges-
For Charges Information Click Below Link-
 
Procedure for Sample Submission-
For users of IIT Roorkee Only
Internal candidates have to first register themselves at following portal-
Obtain a Token ID after logging in to above portal and then submit application (which can be downloaded from below link) mentioning the token ID, registration no. along with other relevant details to the IIC office.
For Downloading application click here-
 
For users other than IIT Roorkee
The Application (duly forwarded by concerned department HOD/Guide) along with analytical charges (in the form of Demand Draft) mentioning all the relevant parameters related to analysis may be sent to the below mentioned address-
Head
Institute Instrumentation Centre
Indian Institute of Technology Roorkee
Roorkee-247667
 
Mode of Payment:
For users of IIT Roorkee Only
The payment may be made in advance (In Cash) at Institute Instrumentation Centre Office.
 
For users other than IIT Roorkee
The payment should be made in the form of a Demand Draft in favor of “Dean SRIC, IIT Roorkee”. The DD should be sent along with your application and Samples.
NOTE: The DD amount should include service tax as per GOI rules.
 
Coordinator
Prof. Institute Instrumentation Centre
Tel:+91-1332-285307/284350
 
Contact Person
Mr. Shiv Kumar
Technical Superintendent
Office Tel: +91-1332-286302
 
Mr. Ravindra Saini
Technical Officer
Office Tel: +91-1332-286292