Thermo gravimetric/ Differential Thermal Analyzer (TG/DTA)
About Instrument and its applications-
The Thermo gravimetric/Differential Thermal Analyzer (TG/DTA) combine the flexibility of DTA with the proven capabilities of the TG measurement capabilities, providing thermal property information for a verity of samples. TG/DTA System can be used for such application as oxidation, heat resistance, amount of water, compositional analysis and measurement of ash contents in a sample. This system is also used to cover such need as reaction rate and accelerated degrading tests.
 
General Information-
Make- EXSTAR
Model- SII 6300 EXSTAR
Year of Installation- 2003 (1 Unit), 2010 (2 Units)
 
Specification-
  • Temperature Range: Ambient to 1500°C
  • Balance type: Horizontal Differential type
  • TG measurement Range/Sensitivity: ±200 mg /0.2µg
  • DTG measurement range: 0.5 mg/min - 1g/min
  • DTA measurement / Sensitivity:     ±1000µV/ 0.06µV
  • Programmable Heating Rate: 0.01 to 100°C/Minute
  • Sample Pan Material: Platinum, Aluminum and Alumina
  • Sample Pan Volume: 45µL
  • Atmosphere: Air, Inert Gas
  • Purge Gas Flow Rate: 0 to 1000 ml/Minute
Sample Requirements-
Amount- ~10-20 mg (in fine powder form)
 
Analytical Charges-
For Charges Information Click Below Link-
 
Procedure for Sample Submission-
For users of IIT Roorkee Only
Internal candidates have to first register themselves at following portal-
Obtain a Token ID after logging in to above portal and then submit application (which can be downloaded from below link) mentioning the token ID, registration no. along with other relevant details to the IIC office.
For Downloading application click here-
 
For users other than IIT Roorkee
The Application (duly forwarded by concerned department HOD/Guide) along with analytical charges (in the form of Demand Draft) mentioning all the relevant parameters related to analysis may be sent to the below mentioned address-
Head
Institute Instrumentation Centre
Indian Institute of Technology Roorkee
Roorkee-247667
 
Mode of Payment:
For users of IIT Roorkee Only
The payment may be made in advance (In Cash) at Institute Instrumentation Centre Office.
 
For users other than IIT Roorkee
The payment should be made in the form of a Demand Draft in favor of “Dean SRIC, IIT Roorkee”. The DD should be sent along with your application and Samples.
NOTE: The DD amount should include service tax as per GOI rules.
 
Coordinator
Prof. Department of Earth Sciences             
Tel:+91-1332-284350, 285307 (Office)
Fax: +91-1332-286303/273560
E-mail: senakfes@iitr.ac.in
 
Contact Person
Sr. Technical Superintendent
Office Tel: +91-1332-286293